| Honeywell’s high capacity, feature-rich VISTA-20PUL is a UL Listed, economical control/communicator that supports up to48 zones of protection using basic hardwired, wired expansion, and/or wireless zones. The VISTA-20PUL also includes Ethernet uploading and downloading capability for Internet and Intranet use via Honeywell’s 7845i or 7845i-ENTcommunications products. The panel’s installation advantages,appealing end-user benefits and robust system capacity make the value-priced VISTA-20PUL an ideal choice for light commercial applications. |
 |
- Ethernet uploading and downloading capability for Internet and Intranet use via 7845i or 7845i-ENT
- Supports four graphic touchscreen keypads
- Wireless keys can be programmed without using zones
- Eight on-board hardwired zones standard (15 when Zone Doublingfeature is used)
- 40 hardwired expansion zones
- 40 wireless expansion zones
- Two low current on-board trigger outputs
- 100 Event Log viewable at system keypads with time/date stamp
- 48 system user codes assignable to either partition
- Expandable to 48 total zones when used with hardwired and/or wirelessexpansion modules
- Two independent partitions plus a common partition
- Global Arming from any system keypad
- Goto function to view or operate one partition from the other
- Separate partition account numbers
- 16 output devices
- Relays (Model 4204 RelayModules, or 4229 ExpansionModule), and/or
- X-10®devices (when used with a 4300 Transformer)
- Four installer configurable zone types allows the installer to create custom zone types by assigning all zone attributes
- Supports four-wire, and up to 16 two-wire smokes
- Works with Sentrol CleanMe™maintenance signal
- Multiple actions on output devicesdepending on system “state”
- Turns lights off when system arms
- Turns the same light on when system disarms
- Flashes same lights when system is in alarm condition
- Built-in phone line cut monitor with programmable delay and annunciation options
- Display on system keypads
- Trigger local sounders
- Trigger system bell
Security Dealer Features
- Automatic System Load Shed
- During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries
- Dynamic Signaling
- Reduces redundant reporting tothe central station when multiple reporting methods are used; i.e.digital dialer and AlarmNet radio
The VISTA-20PUL complies to the following listings
(listed at UL as VISTA 20P & UL-KT):
US Standards: UL LISTING
SUL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar-Alarm System Units
UL 609 - Local Burglar Alarm Units and Systems
UL 365 - Police Station Connected Burglar Alarm Units and Systems
UL 1610 - Central Station burglar Alarm Units
UL 1635 - Digital Alarm Communicator System Units
Canadian Standards: CUL LISTING
SCAN/ULC-S303-M91-STANDARD for Local Burglar Alarm Units and Systems.
ULC Subject C1023-Standard for Household Burglar Alarm System Units.
CAN/ULC-S545-M89-Standard for Residential Fire Warning System Control Units.
CAN/ULC-S304-M88-Standard for Central and Monitoring Station Burglar Alarm Units.
Canadian Electrical Code, Part I.
|